Fujitsu F2MC-8FX Computer Hardware User Manual


 
114
CHAPTER 6 DETAILED RULES FOR EXECUTION INSTRUCTIONS
6.34 INC (INCrement Byte Data of General-purpose Register)
Add 1 to byte data of Ri.
INC (INCrement Byte Data of General-purpose Register)
Operation
(Ri) (Ri) + 1 (Word addition)
Assembler format
INC Ri
Condition code (CCR)
+: Changed by executing instruction
-: Not changed
N: Set to 1 if the MSB is 1 as the result of operation and set to 0 in other cases.
Z: Set to 1 if the result of operation is 00
H
and set to 0 in other cases.
V: Set to 1 if an overflow occurs as the result of operation and set to 0 in other cases.
C: Not changed
Number of execution cycles: 3
Byte count: 1
OP code: C8 to CF
NZVC
+++-