146
CHAPTER 6 DETAILED RULES FOR EXECUTION INSTRUCTIONS
6.50 MOVW (MOVE Word Data from Program Counter to
Accumulator)
Transfer word data from PC to A.
■ MOVW (MOVE Word Data from Program Counter to Accumulator)
Operation
(A) ← (PC) (Word transfer)
Assembler format
MOVW A, PC
Condition code (CCR)
+: Changed by executing instruction
-: Not changed
N: Not changed
Z: Not changed
V: Not changed
C: Not changed
Number of execution cycles: 2
Byte count: 1
OP code: F0
NZVC
----