Gateway 7250R Server User Manual


 
Drives 27
To replace a failed drive:
1 Before you remove the failed drive, use the appropriate software and
utilities installed on the system to stop all activity on the failed drive.
Instructions for using the software are provided by the software
manufacturer.
2 Use the utilities or look at the drive indicator LEDs on the front panel
to determine which drive needs to be replaced.
3 Remove the drive from the drive bay by unclipping the retention lever
and rotating the lever out away from the front of the system.
4 Continue pulling outward until the drive is entirely out of the system,
holding the top edge of the carrier to make sure the drive exits the chassis
smoothly.
5 Remove the four screws that secure the drive to the carrier, then remove
the drive.