GE AF-300 Power Supply User Manual


 
LED
Data Factory Customer
Display Setting Description Setting Setting
6-15
*F_36 0 t o 4 00 HIGH FREQUENCY LIMITER 70 Hz
*F_37 0 t o 4 00
LOW FREQUENCY LIMITER 0 Hz
The high and low limits for the output frequency can be
set within a range of 0 to 400Hz in stages of 1Hz.
NOTE:
If the high and low limit settings are reversed, the high
limit has priority and the low limit is ignored.
*F_38 0 t o 1 0 MOTOR CHARACTERISTICS 5
This adjusts the output current in cases where there is
an irregularity such as current fluctuation. If a current
fluctuation occurs, adjust the setting value while
referring to the tables below.
F_39
DATA INITIALIZATION 0
This resets all Function Codes to factory settings.
0: Inactive (manual setting)
1: Initial values (Initialization with factory defaults)
[Operation Procedure]
When 0 is being displayed, press the STOP +
keys simultaneously to change the display to 1.
In this condition, press the key to reset
all data to the factory default settings. The display
will then automatically switch to show the frequency
setting for STOP mode.
Number of Higher 4 Lower Load High Low
Motor Poles
Setting 0 10 Setting 0 10
FUNC
DATA