HandHeld Entertainment SV Series Scanner User Manual


 
8 - 2 Quick Check® SV Series User’s Guide
Scanning Performance–SV Series Model
Note: All Models - 4 bar codes across maximum (picket fence direction)
Scanner Options
Scanners can incorporate options for special optics and/or be focused for special
applications. Contact Hand Held Products Technical Assistance (see page 9-1)
and describe your application for assistance. Below are two available standard
options.
High Density Focus: Analyze bar codes with 5 mil X dimension
Custom focus distances are available to achieve various spot sizes -- contact
Hand Held Products Technical Assistance (see page 9-1).
Power
+5 volts DC, ± .25 volt
•1 amp maximum
Sync
See "Sync Inputs" on page 2-2 for more details
I/O connector pin 4 input:
TTL switching level threshold
Maximum input voltage swing: +/- 12 VDC
100 K ohm internal pull-up resistor to 5 volts DC
I/O connector pins 1 (+), 2 (-) isolated input:
24 volts DC nominal input for sensing
30 volts DC maximum input, approximately 15 volts minimum for sensing
This input is ground isolated from 5 VDC power
SV100 SV100HD SV100C SV200-1 SV200-2
Analyses/
sec
100 100 100 200 200
Scan
Width
6”
(152mm)
4.5”
(114mm)
10.5”
(267mm)
2.5”
(63.5mm)
1.75”
(44mm)
Focus
Distance
8”
(203mm)
6”
(152mm)
15”
(381mm)
8”
(203mm)
6”
(152mm)
X dim
(min)
.0067”
(.17mm)
.005”
(.127mm)
.013”
(.33mm)
.0067”
(.17mm)
.005”
(.127mm)