6 - 10 Quick Check® SV Series User’s Guide
[~SN###]#scans= 050
[~Lp#]part= 000
[~Lt#]itfp= 001
[DACs]= 175 156 255 255
[~LQ#]p_out= 000
[~Lw,d]def= 000 000
[~L*]pnet= 000
[~LC##]I25min= 002
[~H###]NTrys= 010
[~OS#]Data_Output= 000
[~Hs#]RunSpeed= 000
[~SS######]CntlChars=01 3 010
{hex 5}
T
~Hdx01nnn
Sets scanner gain or offset.
x = value of 1 or 2. If =1, scanner gain is set. If = 2, scanner offset is set.
nnn = gain or offset setting.
For gain, the higher the value, the higher the gain. 225 is the max allowed value.
Example: ~Hd101195 sets the scanner gain setting to a value of 195.
For offset, the higher the value, the lower the offset.
Example: ~Hd201145 sets the scanner offset value to 145.
These commands are best used in conjunction with Hand Held Products’
ScanView software. Please refer to Chapter 4 for descriptions on the use of
these commands.
~Hnx
Sets the number of consecutive scans that do not detect a bar code that cause a bar
code to exit the beam and be reported.
x = values of 2, 3, 4 or 5. The normal setting is 5.
This command is best used in conjunction with the ~SB 1 setting for single scan
operation. Please see ~SBn (page 6-24) command description.
~Hx
Saves the parameters to FLASH (non-volatile memory) from RAM.