HandHeld Entertainment SV Series Scanner User Manual


 
6 - 12 Quick Check® SV Series User’s Guide
~LE#
Exclude the Specified Symbology for a Label: (‘#’ identifies the excluded
symbology:
Values for # are:
~LFxy
Analyze special subsymbology parameters
This command enables special subsymbology parameters within a symbology.
This does not affect the automatic calculations and analyses for mandatory
symbology check digits such as those required in Code 128, UPC/EAN and Code
93.
x = symbology type
y = subsymbology choice for a particular symbology. Current choices include:
Note: Additional subsymbology choices will be added as applications require.
Contact Hand Held Products for details.
Example: ~LF41 = check mod 10 check digit in last location for any I 2 of 5
symbol analyzed
~LF40 = disable any subsymbology analysis for I 2 of 5 symbols
1 UPC/EAN
2 Code 39
3 Code 128
4 Interleaved 2 of 5
5 Code 93
6 Codabar
1 UPC/EAN
2 Code 39
3 Code 128
4 Interleaved 2 of 5
5 Code 93
6 Codabar
0 disabled (default condition)
1 Mod 10 check digit for Inter-
leaved 2 of 5