Quick Check® SV Series User’s Guide 6 - 17
~LV##
Output Interface Mode
## = 00 - 99:
This command sets the output interface mode of the unit. Modes have fixed port
activation logic defined by specific applications. Some activation parameters are
programmable. Custom modes are available – contact Hand Held Products
Technical Support. Modes included in standard SV Series are described in the
"Output Interface Modes Descriptions" on page 6-30. Example: ~LV01 sets
mode 01.
~LX#
Sync Type
~LZ##
Set Number of Codes per Label (i.e., per sync period)
This command sets the exact number of codes to be read during a sync period.
## = the number of codes. For example: ~LZ02 causes a No Read condition to
be set if exactly 2 bar codes are not fully decoded during a sync interval. This
command can also be entered by scanning a bar code. See details in the ~LN##
(page 6-14) command description.
This command overrides the ~LN## command if the number of codes set does
not = 00. If ~LZ## is set to ~LZ00, the ~LN## command takes precedence.
~Lp#
Turn partials on and off at the decoder level for all symbologies.
0 Envelope sync
1 Edge sync
2 Envelope sync w/beam control - leading edge turns
on laser, trailing edge turns off laser
Note: ~LP# sets polarity for Modes 2, 19, and 20
when ~LX2 is set.
3 Edge sync w/beam control - edge turns on beam,
bar code exiting beam turns beam off
Note:
Use ~LS02 setting for sync type ~LX3.
0 Disable
1 Enable