Checks Performed on General Link Settings
The following table displays which checks the Synchronizer performs for
each endpoint when you run an integrity check. Depending on the entity
type synchronized in the link, not all of these checks are performed for
every link.
Check Name Check Description
Endpoint
Connection
Checks that the Synchronizer can successfully connect to
the endpoint using the settings defined.
User permission
check
Checks that the user used to connect to the endpoint has
sufficient permissions to perform the required tasks.
Endpoint
parameters check
Checks and validates additional parameters that may be
defined for the endpoint.
For example, if an alternate root folder is defined for
requirements synchronization, checks that the folder
exists in Quality Center.
Fetching endpoint
schema
Checks that the Synchronizer can obtain the database
schema for the endpoint.
Specified filter
exists
If a filter is defined for the endpoint in the link, checks
that the filter exists in the endpoint.
Subtype exists
check
Checks that the mapped requirement type exists in the
endpoint.
Endpoint events
check
Checks the following;
If the endpoint is set to handle record creation in the
other endpoint, it is also set to update the other
endpoint.
If the endpoint is set to recreate records, the other
endpoint is set to handle record creation.
One endpoint only is set to handle record creation for
the mapped requirement type.