HP (Hewlett-Packard) 3162 Network Card User Manual


 
Configuration Options
C-6
3162-A2-GB20-40August 2000
Sync Data Port Configuration Options
Table C-3. Sync Data Port Configuration Options (1 of 5)
Port Type: E530 (Factory 1) V.35 (Factory 2)
E530 V.35 RS449 X.21
Allows selection of the data port interface type.
E530 Configures the port as an EIA-530-A compatible interface. EIA-530-A DTEs can
be directly connected to a port connector on the back of the DSU/CSU.
V.35 Configures the port as a V.35 compatible interface. V.35 DTEs can be connected
to a port connector using an EIA-530A-to-V.35 adapter cable.
RS449 Configures the port as an RS-449 compatible interface. RS-449 DTEs can be
connected to a port connector using an EIA-530-A-to-RS-449 adapter cable.
X.21 Configures the port as an X.21 compatible interface. X.21 DTEs can be
connected to a port connector using an EIA-530-A-to-X.21 adapter cable.
NOTE: If this configuration option is set to X.21, set the Send All Ones
configuration option to RTS or Disable.
Port Base Rate: Nx64
Nx64 Nx56
Allows selection of the base rate for the data port. The data rate for the port is a multiple
(from 1 to 24) of the base rate specified with this configuration option.
Nx64 Sets the base rate for this port to 64 kbps. The data rate is Nx64 kbps, where N
is a number from 1 to 24.
Nx56 Sets the base rate for this port to 56 kbps. The data rate is Nx56 kbps, where N
is a number from 1 to 24.
Transmit Clock Source: Internal
Internal External
Specifies whether the transmitted data for the port is clocked using an internal clock
provided by the DSU/CSU (synchronized to the clock source specified by the clock
source configuration option) or an external clock provided by the DTE connected to the
port. If an external clock is used, it must be synchronized to the same clock source as
the DSU/CSU.
Internal Indicates the clock is provided internally by the DSU/CSU on the TXC
interchange circuit DB (CCITT 114).
External Indicates the clock is provided externally by the DTE on the XTXC
interchange circuit DA (CCITT 113). Use this selection if the clock source is set to this
data port.