HP (Hewlett-Packard) 3162 Network Card User Manual


 
Configuration Options
C-31
3162-A2-GB20-40
August 2000
Table C-15. SNMP Traps Configuration Options (2 of 3)
General Traps: Both
Disable Warm AuthFail Both
Specifies the general trap types to enable.
Disable Disables the sending of trap messages for warmStart and
authenticationFailure events.
Warm Sends trap messages for warmStart events to the currently configured trap
manager(s).
AuthFail Sends trap messages for authenticationFailure events to the currently
configured trap manager(s).
Both Sends trap messages for warmStart and authenticationFailure events to the
currently configured trap manager(s).
NOTE: This configuration option is not available if the SNMP Traps configuration
option is disabled.
Enterprise Specific Traps: Enable
Enable Disable
Specifies whether enterpriseSpecific traps are enabled.
Enable Sends trap messages for enterpriseSpecific events to the currently configured
trap manager(s).
Disable Disables the sending of trap messages for enterpriseSpecific events.
NOTE: This configuration option is not available if the SNMP Traps configuration
option is disabled.
Link Traps: Both
Disable Up Down Both
Specifies the link trap type to enable. Interfaces monitored for linkUp and linkDown
traps are specified with the Link Trap Interfaces configuration option.
Disable Disables the sending of trap messages for linkDown or linkUp events.
Up Sends trap messages for linkUp events to the currently configured trap
manager(s).
Down Sends trap messages for linkDown events to the currently configured trap
manager(s).
Both Sends trap messages for linkUp and linkDown events to the currently configured
trap manager(s).
NOTE: This configuration option is not available if the SNMP Traps configuration
option is disabled.