HP (Hewlett-Packard) 3162 Network Card User Manual


 
Configuration Options
C-18
3162-A2-GB20-40August 2000
Table C-7. Communication Port Configuration Options (2 of 3)
Data Rate: 9.6
1.2 2.4 4.8 9.6 14.4 19.2 38.4
Configures the bit rate for the communication port.
1.2 Sets the bit rate to 1200 bps (for asynchronous operation only).
2.4 Sets the bit rate to 2400 bps.
4.8 Sets the bit rate to 4800 bps.
9.6 Sets the bit rate to 9600 bps.
14.4 Sets the bit rate to 14,400 bps.
19.2 Sets the bit rate to 19,200 bps.
38.4 Sets the bit rate to 38,400 bps.
NOTE: This configuration option is not available if the communication port is
configured for synchronous operation and the clock source is external.
Character Length: 8
7 8
Configures the character length (7 or 8 bits) for the communication port.
NOTES: This configuration option must be set to 8 if the communication port is
used as the network communication link.
This configuration option is not available if the communication port is
configured for synchronous operation.
Parity: None
None Even Odd
Configures the parity (none, even, or odd) for the communication port.
NOTE: This configuration option is not available if the communication port is
configured for synchronous operation.
Stop Bits: 1
1 1.5 2
Configures the number of stop bits (1, 1.5, or 2) for the communication port.
NOTE: This configuration option is not available if the communication port is
configured for synchronous operation.
Ignore Control Leads: Disable
Disable DTR
Specifies whether the DSU/CSU ignores the state of the Data Terminal Ready (DTR)
input to the communication port.
Disable The control leads are treated in the standard manner.
DTR DTR is ignored.
NOTE: This configuration option is not available if the communication port is
configured for synchronous operation.
Password Required: Disable
Enable Disable
Activates a password prompt that prevents access until a password is entered.
Enable Prompts the communications port user to enter a password.
Disable Does not require a password.