HP (Hewlett-Packard) 3162 Network Card User Manual


 
Configuration Options
C-29
3162-A2-GB20-40
August 2000
SNMP NMS Security Configuration Options
Table C-14. SNMP NMS Security Configuration Options
NMS IP Validation: Disable
Enable Disable
Specifies whether the DSU/CSU validates (for security reasons) the IP address of an
SNMP manager attempting to access the DSU/CSU. Allowable addresses are specified
using the NMS n IP Adr configuration option.
Enable The DSU/CSU validates the IP address of SNMP managers attempting to
access the DSU/CSU.
Disable The DSU/CSU does not validate the IP address of SNMP managers.
Number of Managers: 1
1 2 3 4 5 6 7 8 9 10
Specifies the number of SNMP managers that are allowed to access the DSU/CSU.
NOTE: You must configure an IP address for each SNMP manager that is allowed
access to the DSU/CSU. Allowable addresses are specified using the NMS
n IP Adr configuration option.
NMS n IP Address: Text Field
Text Field Clear
Specifies the allowable IP address of an SNMP manager attempting to access the
DSU/CSU. The manager number (n) is specified by the Number of Managers
configuration option.
Text Field Allows you to edit or display the allowable IP address for the SNMP
manager.
Clear Allows you to clear the allowable IP address for the SNMP manager. The IP
address is set to 000.000.000.000.
Access Level: Read
Read Read/Write
Specifies the allowable type of access for an authorized SNMP manager if IP address
validation has occurred.
Read Allows read-only access (SNMP Get) to the accessible objects in the MIB for
this device. This includes all objects specified as either read-only or read/write in the
MIB RFCs.
Read/Write Allows read and write access (SNMP Get and Set) to the objects in the
MIB for this device. Write access is allowed for all objects specified as read/write in the
MIB RFCs. Read access is allowed for all objects specified as either read-only or
read/write.