HP (Hewlett-Packard) L10 Switch User Manual


 
46 Setting Up an RS-232 Connection
2. Run the terminal emulator application. Configure the terminal emulator to use the
following settings:
3. Press <ENTER> to display the hub configuration Main menu.
If the Main menu does not appear and the following message is displayed, press the
Reset button on the front panel of the hub:
pROBE+>
Setting Up a Connection to a Dumb Terminal
Setting up a connection between a dumb terminal and the hub requires the following
equipment:
FC-AL hub
Any terminal that supports VT100 emulation with no flow control
The terminal must be in vt100 mode before you continue with this procedure. Refer to
the terminals manual for more information.
A null-modem serial cable
The cable must have a DB-9 female connector for connection to the hub.
To establish a connection, do the following:
1. Connect the serial cable between the RS-232 ports on the hub and the terminal.
2. Power on the terminal.
Baud rate: 19,200
Data bits: 8
Parity bits: none
Stop bits: 1
Parity check: off
Flow control: none