HP (Hewlett-Packard) L10 Switch User Manual


 
54 Updating the Hub Firmware
3. From the Main menu, enter 2 (Set Networking parameters) to display the Network
Setup menu.
Network Setup Menu:
1. Return to Main Menu
2. Select IP address [current = nnn.nnn.nnn.nnn]
3. Select Subnetworking Mask [current = nnn.nnn.nnn.nnn]
4. Select Default Gateway address [current = nnn.nnn.nnn.nnn]
5. Save Network Setup changes and reboot
6. Proxy Master Setup
4. Enter 6 to display the Proxy Master menu:
Proxy Master Menu: <Current state: Proxy Master DISABLED>
1. Return to previous Menu
2. Toggle current Proxy Master state and reboot
5. Enter 2 to change the Proxy Master setting to ENABLED and reboot the hub. When the
Main menu appears, verify the new Hub Controller version.
Procedure 6: Set Manufacturing Values
After resetting the hub and verifying the new firmware versions, set the system.sysDescr
and system.sysObjectID values.
1. From the Main menu, enter mfg to display the Manufacturing Settings Menu.
Manufacturing Settings Menu:
1. Return to Main Menu
2. Set sysdescr [current = ]
3. Set system OID [current = 1.3.6.1.4.1]
4. Toggle port bypass persistence mode [current = Enabled]
>
2. Enter 2 to display the Set sysDescr string Menu.
Set sysDescr string Menu: [current = ]
1. Return to Manufacturing Settings Menu
or enter new sysDescr string
>