78 If the Management Server Cannot Ping the Hub
If the Management Server Cannot Ping the Hub
If you cannot ping the hub from the management server (host) where Fibre Channel
Manager is or will be installed, find the symptom that best fits the situation, then attempt
the solution. When more than one solution is possible, the most likely one is listed first.
Symptom Cause/Solution
You cannot ping the hub and the
hubs 10Base-T port LED is off.
The ethernet cable is not connected properly. Verify that
the ethernet cable is securely connected to the hub and the
management server.
The ethernet cable is faulty. Connect another ethernet
cable between the management server and hub.
You cannot ping the hub and the
hubs 10Base-T port LED is on.
The IP address used to ping the hub is incorrect. Verify
that you typed the correct IP address when pinging the hub.
One or more of the hubs addresses are incorrect.
Display the hubs serial interface as described in chapter3,
RS-232 Interface Functions. Verify that the hubs IP,
subnetworking mask, and default gateway addresses are
correct.
If you do not enter 5. Save Network Setup changes and
reboot, the addresses you enter are not saved.