3-26 Troubleshooting and Diagnostics Technology Code ID)
Beep Code Message Description
(None) RAM ERROR AT LOCATION xxxxxx :
WROTE : xxxx
READ : xxxx
RAM failed during memory test at the indicated
location.
(None) PARITY ERROR AT UNKNOWN
LOCATION
Parity error during memory test at unknown
location.
(None) PARITY ERROR AT LOCATION xxxxxx Parity error during memory test at the indicated
location.
(None) NO INTERRUPTS FROM TIMER 0 Timer 0 of the clock timer controller does not
generate system interrupts correctly.
(None) UNEXPECTED AMOUNT OF MEMORY -
RUN SCU
System memory size does not match the CMOS
record.
(None) CLOCK NOT TICKING CORRECTLY System clock does not work correctly.
(None) TIME/DATE CORRUPT - RUN SCU Time/date information in CMOS is invalid.
(None) MACHINE IS LOCKED - TURN KEY Keyboard operation is locked.
(None) BOOT SECTOR 0 HAS CHANGED Hard disk boot sector has been changed,
probably because of a virus attack.
(None) Suspend-to-Disk partition MISSING! No Suspend-to-Disk partition found.
(None) Hard Disk ERROR! Access to the Suspend-to-Disk partition failed.
(None) Suspend-to-Disk partition signature NOT
FOUND!
No Suspend-to-Disk partition signature found.
(None) Suspend-to-Disk partition size TOO
SMALL!
Suspend-to-Disk partition has insufficient
capacity.
(None) MEMORY SIZE HAS CHANGED --
REBOOTING
Memory size has changed after previous
Suspend-to-Disk operation.
Sycard PCCtest 450/460 CardBus Card (Optional)
The PCCtest 450 and 460 CardBus Cards (version 1.05) available from Sycard Technology are the
only recommended diagnostic tool that tests the functionality of the PCMCIA slots using a PCMCIA
card. Each is a Type II PC Card that works with compatible test software to exercise PCMCIA
functions. (For details, see the Sycard Technology Web site: http://www.sycard.com.)
The PCCtest product contains these components:
PCCtest 450 or 460 (revision 1.05) PC Card.
PCCtest 450/460 test software disk. (Software updates are available at the Sycard Technology
Web site: http://www.sycard.com.)
Configuration headers (PC Card/16-bit and CardBus/32-bit) that attach to the card.
You will also need a CardBus extender card (such as the Sycard PCCextend 70) to avoid wear on the
Sycard PCMCIA connector.
The Sycard PCCtest 450 and 460 provide the following tests. See the Sycard documentation for
details about running the tests.
Table 3-4. Sycard PCCtest Commands
Slot PCMCIA PC Card (16-bit) test
(PC Card configuration header)
CardBus (32-bit) test
(CardBus configuration header)
zt1000/xz300/xt1500
(technology code ID)
N/A PCT450 -bc1b -0 -v TESTCB -b92b -0 v