IBM 1483DSV Personal Computer User Manual


 
2-2 701344-003
Customer Installation
For units operating at 200–240V: The power cable required for domestic units is a
UL listed, CSA certified, 18/3 AWG, type SVT or SJT cable (15-foot [4.6-meter]
maximum). It is terminated on one end by a 250V, 15A grounding type attachment
connector. It is terminated at the other end by a 250V, 15A tandem blade, grounding type
attachment plug.
The power cable required for international units is an 18/3 AWG, type SJT cable
(15-foot [4.6-meter] maximum). It is terminated on one end by a 250V, 15A grounding
type attachment plug body. It is terminated at the other end by a 250V, 15A grounding
type cord connector. The cord set is marked HAR to signify appropriate safety
approvals. The socket outlet must be nearby and easily accessible, per IEC 950 Sec.
1.7.2.
The installation site must provide a properly wired and grounded power outlet. Circuits
connected to air conditioners and devices that generate significant transient electrical
noise should be avoided.
Electrostatic discharge in the vicinity of the unit should be minimized by avoiding high
resistance floor material and carpeting that does not have antistatic properties, by avoiding
the use of plastic seats and covers, and by avoiding low humidity levels. The unit should
be located away from areas that generate electromagnetic interference (for example,
transformers, power distribution panels, welding equipment, motors, transmitters). Do
not put the unit next to fluorescent lights. The 1483 should not be installed where the
atmosphere contains corrosive elements that can damage the unit.
Do not run the cable in areas that produce electromagnetic interference (for example,
near transformers, switching equipment, welding equipment, power distribution
panels, and under carpets where vacuum cleaning is done). Also, do not roll heavy
equipment over the cable.
Inspecting the Packages
Before you unpack the Display element, Logic element, and Keyboard element, inspect
the carton for physical damage.
If the exterior package is damaged, contact your local MTX Inc. sales office or
distributor. Also contact the carrier to request examination of the damage. The carrier
is required to complete and sign a damage report form.
Note: To report damage, customers in the Continental US should call MTX Inc.
toll-free at 1-888-648-7826 and ask for the Customer Service Department.
If the package is not damaged, remove the package contents.