IBM 201 Computer Monitor User Manual


 
POST error messages
Table 17 provides information about the POST error messages that can appear
during startup.
Note that these diagnostic error messages require the attachment of a monitor,
keyboard, and mouse (before you power on the system) to enable you to see them.
In the following error messages, X can be any number or letter.
Table 17. POST error messages
Error
code/Symptom
Meaning FRU/action
062 Three consecutive boot
failures using the default
configuration
1. Run Configuration/Setup
2. Battery
3. System board
4. Processor
101, 102 System and processor error System board
106 System and processor error System board
111 Channel check error
1. Failing ISA Adapter
2. DIMM
3. System board
114 Adapter read-only memory
error
1. Failing Adapter
2. Run Diagnostics
129 Internal cache error
1. Processor
2. Optional processor (if installed)
151 Real-time clock error
1. Run Diagnostics
2. Battery
3. System board
161 Real-time clock battery error
1. Run Configuration/Setup
2. Battery
3. System board
162 Device Configuration error
1. Run Configuration/Setup
Note: Be sure to load the default settings and any
additional desired settings; then, save the configuration.
2. Battery
3. Failing Device
4. System board
163 Real-time clock error
1. Run Configuration/Setup
2. Battery
3. System board
164 Memory configuration
changed
1. Run Configuration/Setup
2. DIMM
175 Hardware error System board
92 NAS 200 Users Reference