IBM 201 Computer Monitor User Manual


 
Table 18. Diagnostic error messages (continued)
Error Code Meaning FRU/action
166-342-000 System Management failed:
Remote Supervisor Adapter
BIST indicate failed tests).
1. Ensure that the latest firmware levels for the Remote
Supervisor Adapter and BIOS
2. Disconnect all server and option power cords from the
unit, wait 30 seconds, reconnect, then retry.
3. Remote Supervisor Adapter
166-400-000 System Management failed:
System management
hardware on system board
failed) (ISMP Self Test Result
failed tests: x where x =
Flash, RAM, or ROM).
1. Re-flash or update firmware for ISMP
2. System board
180-XXX-000 Diagnostics LED failure Run the diagnostics LED test for the failing LED.
180-XXX-001 Failed front LED panel test
180-XXX-002 Failed diagnostics LED panel
test
1. System board
2. Power-switch assembly
180-XXX-005 Failed SCSI backplane LED
test
1. SCSI backplane
2. SCSI backplane cable
3. System board
180-XXX-006 Memory Board LED test Suspected part:
1. Memory
2. Processor/PCI board
3. System board
180-361-003 Failed fan LED test
1. Fans
2. System board
201-XXX-0NN Failed Memory test
1. DIMM Location DIMM1 - DIMM4 where NN can be a
value from 01 to 04. 01 = DIMM2, 02 = DIMM1, 03 =
DIMM4, 04 = DIMM3
2. System board
201-XXX-999 Multiple DIMM failure; see
error text for failing DIMMs
1. See error text for failing DIMMs
2. System board
202-XXX-001 Failed system cache test
1. VRM 1
2. Microprocessor 1
202-XXX-002 Failed system cache test
1. VRM 2
2. Microprocessor 2
206-XXX-000 Failed diskette drive test
1. Cable
2. Diskette drive
3. System board
215-XXX-000 Failed IDE CD-ROM test
1. CD-ROM drive cables
2. CD-ROM drive
3. System board
217-198-XXX Could not establish drive
parameter
1. Check cable and termination
2. SCSI backplane
3. Fixed disk
Appendix C. Engine POST messages 103