Chapter 6. Solving problems 91
035 ServeRAID Aborted Test setup error: No ServeRAID adapter found on
system board or PCI bus
Make sure that the
ServeRAID adapter is
properly installed. If the
problem remains,
replace the ServeRAID
adapter. If the problem
persists, call for service.
Failed Adapter in slot n; adapter/drive configuration error
(where n is the slot number of the failing adapter)
Run the ServeRAID
Configuration Utility.
If the problem remains,
replace the ServeRAID
adapter in slot n.
If the problem persists,
call for service.
Adapter in slot n; internal error
(where n is the slot number of the failing adapter)
Logical drive m on adapter in slot n
(where m is the number of the failing logical drive
and n is the slot number of the adapter)
On system board; internal error Run the ServeRAID
Configuration Utility.
If the problem persists,
call for service.
On system board; adapter/drive configuration error
Logical drive on system board adapter
Adapter in slot n; memory allocation error
(where n is the slot number of the failing adapter)
Call for service.
On system board; memory allocation error
On system board; PCI configuration error
On system board; POST error
Adapter in slot n; POST error
(where n is the slot number of the failing adapter)
Replace the ServeRAID
adapter in slot n. If the
problem persists, call for
service.
Adapter in slot n; PCI configuration error
(where n is the slot number of the failing adapter)
SCSI drive on adapter in slot n, SCSI ID m
(where n is the slot number of the adapter and m is
the SCSI ID of the drive)
Check the cable and
power connections on
the drive. If the problem
persists, call for service.
075 Power supply Failed Voltage sensed by the system is out of range Call for service.
Code Function Result Text message Action