IBM 220 Computer Monitor User Manual


 
Chapter 6. Solving problems 93
Microprocessor Failed VRM corresponding to Microprocessor in socket xyz
is defective
(where xyz identifies the microprocessor whose VRM
is causing the error message)
Replace the VRM.
If the problem remains,
call for service.
VRM corresponding to Microprocessor in socket id
xyz is not installed
(where xyz identifies the microprocessor whose VRM
is causing the error message)
Install a VRM.
If the problem persists,
call for service.
175 System thermal Failed Fan # n
(where n is the number of the failing fan)
Replace the indicated
fan.
Temperature sensed on processor board is out of
range
Call for service.
180 Status display Failed Any failure message Call for service.
201 System memory Failed DIMMs in location DIMM n
(where n is the number of the socket that contains the
failing DIMM)
1. Reseat the failing
DIMM.
2. If the problem
remains, replace the
DIMM.
If the problem
persists, call for
service.
Test setup error: Corrupt BIOS in ROM If your server does not
have the latest level
BIOS installed, update
the BIOS to the latest
level.
If the problem persists,
call for service.
Test setup error: Corrupt DMI BIOS, information in
BIOS is not as expected
Code Function Result Text message Action