IBM 71453RU Server User Manual


 
Handle
Installation
tool
Microprocessor
10. Carefully position the microprocessor with the microprocessor tool over the
microprocessor socket. Twist the microprocessor tool counterclockwise to
insert the microprocessor into the socket.
11. Close the load plate and then rotate the microprocessor-release lever to secure
the microprocessor.
Note: If you have more microprocessors to install, repeat steps 5-11 for each
microprocessor, and then continue with step 12 after you have installed all the
microprocessors that you plan to install.
12. Remove the heat sink from its package and rotate the heat-sink handle to the
fully open position.
13. Remove the cover from the bottom of the heat sink.
14. Position the heat sink above the microprocessor and align the clips of the heat
sink with the tabs next to the microprocessor socket.
Chapter 2. Installing optional devices 77