b. Return to “Step 0620-001” on page 1-17.
Table 1-6. SP Switch2 error conditions
Error # Device Message Link Message Description and Action
2 Initialized N/A Description: Initialization detected a wrapped port where a
processor node was expected (this may result from isolation
procedures), or else a disconnected cable.
Action:
1. If this is an unexpected condition, check cabling
against the configuration file
var/adm/SPlogs/cssX/p0/out.top (where X=0 or 1) and
review the appropriate miswire file,
var/adm/SPlogs/cssX/p0/cable_miswire (where X=0 or
1).
2. If the processor node can be reconnected, remove
the wrap plug and connect the data cable between the
switch assembly and the processor node.
3. If the processor node is to be permanently removed,
have the customer update the switch topology.
4. If problem is on board connection, as indicated by
out.top or Estart_sw: 0028-331 Note: 1 switch to switch
links did not initialize. Switch performance may be
affected. Run the switch wrap-test described in
“Running diagnostics on a switch port” on page 3-12.
5. Repeat “Step 0620-001” on page 1-17 for next problem
or go to “Step 0620-021” on page 1-27 to verify fix.
Switch Function (MAP 0620)
Chapter 1. Maintenance Analysis Procedures (MAPs) 1-19