the field. The field list must be enclosed with parenthesis. Only the attributes stated are changed
and the other attributes default to what was statically defined. A field defined originally as RED and
UNDERLINE remains underlined if only blue is stated dynamically.
ALarm
(specified for SEND and CONVERSE only) sounds the bell when displaying panel. (The default is no
alarm).
NOErase
(specified for SEND and CONVERSE only) do not erase the screen before displaying this one. (The
default is erase before a panel write).
POsition()
(specified for SEND, CONVERSE, and RECEIVE only) positions the panel on the output screen. Row
(row) and column (column) specifies where the top left corner of the panel should begin. (The default
is row 1 col 1). For example, POS(5 10) means to have the panel start in row 5 and column 10, the
actual movement is 4 rows down and 9 columns to the right.
FReekb
(specified for SEND and CONVERSE only) frees the keyboard, allowing operator input. (This is the
default.)
LOckkb
(specified for SEND and CONVERSE only) locks the keyboard.
CLrinput
(specified for SEND and CONVERSE only) clears all input fields before displaying the panel. Variable
substitution is not attempted and pad characters fill the input area.
Options
UNProtect
specifies that the field is not protected from operator input.
PRotect
specifies that the field is protected from operator input.
SKip
specifies a protected field with the auto-skip feature. Operator entering a character in the last position
of the previous unprotected field causes the cursor to skip over this field.
NORmal
specifies that the field is not highlighted.
BRight
specifies that the field is highlighted.
INVisible
specifies that the field is invisible.
GReen
RED
BLUe
TUrquoise
WHite
YEllow
PInk
DEfcolor
are the choices for the color.
Panel Facility
304
CICS TS for VSE/ESA: REXX Guide