Table 17. MCT command definitions (continued)
DEC HEX MCT Default Min Max
204 CC Scan
1
storage template #2 predefined
location X3
205 CD Scan
1
storage template #2 predefined
location Y3
206 CE Scan
1
storage template #2 predefined
location DX3
207 CF Scan
1
storage template #2 predefined
location DY3
Notes:
1. See “Store scanned image and/or select partial image for retrieval” on page 169
Setup commands
Setup commands change character font, intercharacter spacing, and the target print
station.
Set print mode
EIA-232 Syntax:
ESC ! n or X'1B;21;n'
where:
n Specifies print characteristics, such as user-defined thermal and
impact code pages.
Bit Number Function Bit=0 Bit=1 Thermal Impact
(LSB) 0 Char/Page 0 See Below See Below yes yes
1 Char/Page 1 See Below See Below yes yes
2 Overline Cancel Set yes no
3 Emphasized Cancel Set yes yes
4 Double-high Cancel Set yes yes
5 Double-wide Cancel Set yes yes
6 Inverted Mode Cancel Set yes no
(MSB) 7 Underlined Cancel Set yes no
Table 18. Fonts for Models TI3, TI4, TG3, TG4, TG8, TG9, TI8, TI9, TF6, and TM6
Bit 0 Bit 1 User-Defined Thermal
Code Page
User-Defined Impact Code
Page @ Density
Resident
Thermal
Resident
Impact
0 0 Code Page 1 Code Page 1 @ 150 half-dots
per inch
Font A Font A
1 0 Code Page 2 Code Page 1 @ 120 half-dots
per inch
Font B Font B
0 1 Code Page 3 Code Page 2 @ 150 half-dots
per inch
Font C Font A
1 1 Code Page 4 Code Page 2 @ 120 half-dots
per inch
Reserved Font B
1.
Updated April 2, 2009
Appendix D. EIA-232 programming information 129