IBM TI4 Printer User Manual


 
Retrieve next image location
EIA-232 syntax:
GS N SOH NULL or X'1D 4E 01 00'
Remarks:
Returns the table position where the next image is stored. Command is
Extend MCT Request command (2-byte address). Status byte 5, bit 3 is set
to indicate data is attached.
Retrieve first unread image location
EIA-232 syntax:
GS N SOH SOH or X'1D 4E 01 01'
Remarks:
Stored images are searched sequentially, and the first location that has not
been set to read is returned. The command is Extend MCT Request
(2-byte address). Status byte 5, bit 3 is set to indicate data is attached.
Select compression format and scanned image threshold
EIA-232 syntax:
X'1B;4d;x;n1;n2'
where:
v x = X'1F'
address to store data
v n1
00 200 DPI TIFF-CCITT-Group 4 compression
01 200 DPI JPEG compression
02 200 DPI BMP (uncompressed)
04 200 DPI TIFF file, no compression (gray scale)
10 100 DPI TIFF-CCITT compression (black and white)
11 100 DPI JPEG compression (gray scale)
12 100 DPI BMP (uncompressed gray scale)
14 100 DPI TIFF File (no compression)
v n2
Lightens or darkens the contrast of a scanned image. Higher numbers
print darker.
Remarks:
The current format applies to retrieval and storage of the currently scanned
image. Changing the format does not change the format of any images
already stored in flash. The setting is persistent across reset and power
cycles.
Table 26. Average size for a personal check with little background data
Compression type Size
00 - TIFF-CCITT compression - 200 DPI 5K Bytes
01 - JPEG compression - 200 DPI 45K Bytes
02, 04 - no compression - 200 DPI 660K Bytes
10 - TIFF-CCITT - 100 DPI 3.5K Bytes
Updated April 2, 2009
174 SureMark Printers User’s Guide