Intel 654655-001 Switch User Manual


 
44
CHAPTER 2
Intel Express 100BASE-TX Switching Hub
VLAN commands
Use VLANs to limit the broadcast domain and establish security
virtual LANs. See the procedure on page 22 on creating VLANs.
run
indicates that only the currently running configuration is
changed. Changes are not restored after a reset.
nvram
indicates that only the configuration stored in NVRAM is
changed. Changes do not take effect until a reset.
all
indicates that both the currently running configuration and the
NVRAM configuration is changed. Changes take effect
immediately and are restored after a reset.
get-con-matrix
Displays the current connectivity matrix for the switch. The first
column is the source port. The other columns are destinations where
frames from a given source port can be forwarded. Unlearned
addresses (addresses that aren’t in the switching database) are
forwarded to all ports marked with a + in the source port’s row.
Learned addresses are forwarded to their destinations only if the
destination is marked with a + in the source port’s row. Ports don’t
need to be forwarded to themselves.
SYS_console> get-con-matrix
VLAN CONNECTIVITY MATRIX
==========================
SRC PORT to : P1 P2 P3 P4 P5 P6 P7
===========================================
1 - - + + + + +
2 + - + + + + +
3 + - - + + + +
4 + - + - + + +
5 + - + + - + +
6 + - + + + - +
7 + - + + + + -
get-vbc-matrix
Displays the current broadcast domain matrix for the switch. See the
get-con-matrix command above for a description of the resulting
table. Here, only the broadcast address is affected.