IXD1110 Demo Board
Development Kit Manual 21
Document Number: 250807
Revision Number: 003
Revision Date: June 27, 2003
8.4 Mictor Connectors
Table 8 provides a detailed list of the Mictor Connector test points that are available using Mictor
Connectors and that are designed for easy use with the Tektronix* P6434 Mass Termination Probe.
Using these connectors with a Tektronix* logic analyzer allows the probing of the signals in
Table 8.
DTP11 I
2
C_DATA_4 E23 I
2
C_DATA_4 for IXF1110
DTP12 I
2
C_DATA_5 H24 I
2
C_DATA_5 for IXF1110
DTP13 I
2
C_DATA_6 G20 I
2
C_DATA_6 for IXF1110
DTP14 I
2
C_DATA_7 E22 I
2
C_DATA_7 for IXF1110
DTP15 I
2
C_DATA_8 G24 I
2
C_DATA_8 for IXF1110
DTP16 I
2
C_DATA_9 F24 I
2
C_DATA_9 for IXF1110
Table 7. GBIC Test Points (Sheet 2 of 2)
Test Point Symbol
IXF1110 Ball
Designator
Description
NOTE: DTP = Differential Test Point
Table 8. Mictor Connector Test Points (Sheet 1 of 2)
Probe
A
CPU Data
Bus
IXF1110
Ball
Designator
Probe
C
Address
Bus and
Other
IXF1110
Ball
Designator
Probe
D
Pause I/F
and Reset
Signals
IXF1110
Ball
Designator
A0(0) uPx_Data0 B3 C0(0) TA – D0(0) –
A0(1) uPx_Data1 A4 C0(1) Start_XFER – D0(1) –
A0(2) uPx_Data2 B9 C0(2) RD/~WR – D0(2) –
A0(3) uPx_Data3 A7 C0(3) Gen_PCsN – D0(3) –
A0(4) uPx_Data4 C12 C0(4) – D0(4) –
A0(5) uPx_Data5 E11 C0(5) CsN – D0(5) –
A06) uPx_Data6 C13 C0(6) Bus_request – D0(6) –
A0(7) uPx_Data7 A8 C0(7) Bus_Busy – D0(7) –
A1(0) uPx_Data8 A10 C1(0) Bus_Grant – D1(0) –
A1(1) uPx_Data9 A9 C1(1) – D1(1) –
A1(2) uPx_Data10 E12 C1(2) uPx_RdyN C22 D1(2) –
A1(3) uPx_Data11 A11 C1(3) – D1(3) –
A1(4) uPx_Data12 G12 C1(4) uPx_CsN F20 D1(4) –
A1(5) uPx_Data13 E10 C1(5) uPx_WrN A18 D1(5) –
A1(6) uPx_Data14 F11 C1(6) uPx_RdN H14 D1(6) POR –
A1(7) uPx_Data15 D7 C1(7) – D1(7) HRESET –
A2(0) uPx_Data16 D14 C2(0) uPx_Add0 J1 D2(0) –
A2(1) uPx_Data17 C14 C2(1) uPx_Add1 G4 D2(1) –
A2(2) uPx_Data18 F14 C2(2) uPx_Add2 F3 D2(2) –
1. For evaluation of the signals provided by the Mictor connector, use the corresponding logic analyzer probe.