Intel S5000XAL Server User Manual


 
Intel
®
Server Board S5000PAL / S5000XAL TPS Connector / Header Locations and Pin-outs
Revision 1.4
Intel order number: D31979-007
45
Connector Quantity Reference Designators Connector Type Pin
Count
System Recovery
Setting Jumpers
4 J1D1, J1D2, J1D3, J3H1 Jumper 3
5.2 Power Connectors
The main power supply connection is obtained using an SSI compliant 2x12 pin connector (J3K3). In
addition, there are two additional power related connectors; one SSI compliant 2x4 pin power connector
(J3K4) providing support for additional 12V, and one SSI compliant 1x5 pin connector (J1K1) providing
I
2
C monitoring of the power supply. The following tables define the connector pin-outs.
Table 11. Power Connector Pin-out (J3K3)
Pin Signal Color Pin Signal Color
1 +3.3Vdc Orange 13 +3.3Vdc Orange
2 +3.3Vdc Orange 14 -12Vdc Blue
3 GND Black 15 GND Black
4 +5Vdc Red 16 PS_ON# Green
5 GND Black 17 GND Black
6 +5Vdc Red 18 GND Black
7 GND Black 19 GND Black
8 PWR_OK Gray 20 RSVD_(-5V) White
9 5VSB Purple 21 +5Vdc Red
10 +12Vdc Yellow 22 +5Vdc Red
11 +12Vdc Yellow 23 +5Vdc Red
12 +3.3Vdc Orange 24 GND Black
Table 12. 12V Power Connector Pin-out (J3K4)
Pin Signal Color
1 GND Black
2 GND Black
3 GND Black
4 GND Black
5 +12Vdc Yellow/Black
6 +12Vdc Yellow/Black
7 +12Vdc Yellow/Black
8 +12Vdc Yellow/Black
Table 13. Power Supply Signal Connector Pin-out (J1K1)
Pin Signal Color
1 SMB_CLK_ESB_FP_PWR_R Orange
2 SMB_DAT_ESB_FP_PWR_R Black
3 SMB_ALRT_3_ESB_R Red
4 3.3V SENSE- Yellow
5 3.3V SENSE+ Green