Intel
®
Server Board S5000PAL / S5000XAL TPS Appendix B: Sensor Tables
Revision 1.4
Intel order number: D31979-007
87
Table 44. BMC Sensors
Sensor
Name
Sensor
Number
System
Applica-
bility
Sensor Type Event /
Reading
Type
Event Offset
Triggers
Criticality Assert /
De-assert
Readable
Value /
Offsets
Event Data Rearm Standby
Power down
Power cycle
A/C lost
OK
Soft power
control failure
Power unit
failure
Critical
Power Unit
Status
01h All Power Unit
09h
Sensor
Specific
6Fh
Predictive
failure
Non-Critical
As – Trig Offset A X
Redundancy
regained
Non-red: suff
res from redund
OK
Redundancy
lost
Redundancy
degraded
Degraded
Non-red: suff
from insuff
OK
Non-red:
insufficient
Critical
Power Unit
Redun-
dancy
02h Chassis-
specific
Power Unit
09h
Generic
0Bh
Redun degrade
from full
Redun degrade
from non-
redundant
OK
As – Trig Offset A X