Intel S5000XAL Server User Manual


 
Appendix B: Sensor Tables Intel
®
Server Board S5000PAL / S5000XAL TPS
Revision 1.4
Intel order number: D31979-007
92
Sensor
Name
Sensor
Number
System
Applica-
bility
Sensor Type Event /
Reading
Type
Event Offset
Triggers
Criticality Assert /
De-assert
Readable
Value /
Offsets
Event Data Rearm Standby
Non-red:
insufficient
Critical
Redun degrade
from full
Redun degrade
from non-
redundant
OK
Presence OK
Failure Critical
Predictive fail Non-Critical
A/C lost Critical
Power
Supply
Status 1
70h Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
Configuration
error
Non-Critical
As and De Trig Offset A X
Presence OK
Failure Critical
Predictive fail Non-Critical
A/C lost Critical
Power
Supply
Status 2
71h Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
Configuration
error
Non-Critical
As and De Trig Offset A X
Power
Nozzle
Power
Supply 1
78h Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc] Threshold
defined
As and De Analog R, T A
Power
Nozzle
Power
Supply 2
79h Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc] Threshold
defined
As and De Analog R, T A
Power
Gauge
V1 rail
(+12v)
Power
Supply 1
7Ah Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc] Threshold
defined
As and De Analog R, T A