Appendix B: Sensor Tables Intel
®
Server Board S5000PAL / S5000XAL TPS
Revision 1.4
Intel order number: D31979-007
86
Rearm Sensors
- The rearm is a request for the event status for a sensor to be rechecked and updated upon a
transition between good and bad states. Rearming the sensors can be done manually or
automatically. This column indicates the type supported by the sensor. The following
abbreviations are used in the comment column to describe a sensor:
A: Auto-rearm
M: Manual rearm
Default Hysteresis
- Hysteresis setting applies to all thresholds of the sensor. This column provides the count of
hysteresis for the sensor, which can be 1 or 2 (positive or negative Hysteresis).
Criticality
- Criticality is a classification of the severity and nature of the condition. It also controls the
behavior of the Control Panel Status LED.
Standby
- Some sensors operate on standby power. These sensors may be accessed and / or
generate events when the main (system) power is off, but AC power is present.