Interphase Tech 5535 PRI Network Card User Manual


 
Displaying and Saving Events
92 Interphase Corporation
NOTE
If you want to test more than two B channels or more than
one port simultaneously, launch several instances of the
utility and repeat steps 2 to 4 for each channel or port.
(You can change the number of frames sent if you want a
longer test—see Setting the Number of Frames to Send on
page 93).
5. To re-enable the RAS Server:
a. From the Start menu, select Programs, then
Administrative Tools (Common), and then
Remote Access Admin.
b. From the Server menu, select Start Remote Access
Service.
c. If Windows NT does not display the name
automatically, enter the server name preceded by
two backslashes (\\). To determine the server name,
see
Index of Common Tasks on page 115.
d. Click OK.
Displaying and Saving Events
The event list is an additional window at the bottom of the
LoopTest main dialog that displays communication events,
such as communication established between the two B
channels, and data being sent on one B channel.
To show or hide the LoopTest event list: