3.11 Troubleshooting FastManage
The following table lists problems that may occur with FastManage; it also
lists possible solutions.
3.11.1 Error Messages
The following table contains error messages that you may see while using
the FastManage Network Manager.
Problem Solution
SNMP community strings are
defaulted to public and private
Change the community strings in the
issnmp.ini Þle
Unable to start the FastManage
application. A message such as
ÒUnable to start protocol stackÓ
displays
Restart Windows.
Applications start, but do not display
connected ports or SNMP statistics
Restart Windows. Verify Þrmware agent
is compatible with FastManage
Can not start applications and the
message ÒIP_STACK section
issnmp.ini Þle needs IPADDR= setÓ
appears
Reinstall FastManage with IP and IPX
protocols.
The message ÒUnable to Þnd and
start net driverÓ appears
Load IPX drivers before starting
Windows.
The message ÒNo Netware
connections foundÓ when running
Discovery or ÒHost not in IPX binderyÓ
appears
Load VLM.EXE before starting
Windows.