A-61140 January 2000 2-7
Adjusting the feed
shelf position (semi-
automatic feeder only)
For manual feeding, the feed shelf can be adjusted in the 0°, 30° or 40°
position. For automatic feeding, raise the feed shelf to the 30° or 40°
position.
40° position
30° position
Adjusting the side
guides
Before you begin feeding documents into the scanner, adjust the
position of the side guides and feed shelf position.
• Adjust the width of the feed shelf side guides to hold the widest
document you will be scanning. Leave approximately 1/16-inch
(2 mm) clearance on each side of the largest document to allow for
proper feeding.
NOTE: Ensure that the documents are center-fed so each
document covers the 2 ½-inch required width as indicated
by the label on the feed tray.