A-61140 January 2000 5-11
4. Lift up and latch the horizontal transport plate into its open position.
NOTE: If the Patch Reader accessory is installed, it must be
removed from the mounting plate in order to lift up the
horizontal transport plate.
5. Vacuum the lower belt module and transport belts.
WARNING: Do not make contact with any electrical
components when vacuuming inside the scanner.
6. Release and lower the horizontal transport plate back into its original
position.
7. Lower the release bar and latch the front scan module into its
original position.
8. Close the lower access door.