FS-1010
5-14
(3) Removing the power supply board and high voltage board
1. Remove the process unit (See page 5-4).
2. Remove the top cover/face-down output tray and left cover (See pages 5-5 and 5-6).
3. Remove three connectors 1 from the power supply board 2.
4. Remove eight screws 3.
5. Remove the power supply board 2 and high voltage board 4. (Note: The high voltage board
4 is directly connected to the bias board 5.)
6. Separate the high voltage board 4 from the power supply board 2.
Figure 5-2-13 Removing the power supply board and high voltage board
3
2
1
4
5
3