Setting the Auto Continue Recovery Time
Follow the procedure given below to change the recovery time for Auto
Continue.
1
Press [MENU].
2
Press U or V repeatedly until Others >
appears.
3
Press Z.
4
Press U or V repeatedly until >Auto
Error Clear > appears.
5
Press Z and display >>Error Clear.
6
Press [OK]. A blinking cursor (_) appears.
7
Press U or V to increase or decrease the value of the figure where the
cursor is blinking and set the desired time. The time must be set between
000 and 495 seconds, in 5-second increments. If set to 000, printing will be
continued immediately without allowing any time interval. You can use Z
and Y to move the cursor right and left.
8
Display the desired time and press [OK].
9
Press [MENU]. The message display returns to Ready.
Others >
>Auto Error >
Clear On
>>Error Clear
Timer 030
sec.