Lantronix Hub Switch User Manual


 
MSS User Guide 2: Installation
2-6
MSS-VIA Specifications
Power (power cube adaptor)
Adapter:
Input: 100-240 VAC Universal Power Supply with International
Adapters
Output: 12 VDC Max
Current: 1A @ 12 V
MSS-VIA power input range: 7-24 VDC
Temperature
Note: Rapid temperature changes may affect operation. Do not operate near heating or
cooling devices or areas that open to the outdoors.
Operating range: 5° to 50° C (41° to 122° F)
Storage range: 40° to 66° C (-40° to 151° F)
Max. temp change: 20° C (36° F) per hour
Humidity
Operating range: 10% to 90% non-condensing
40% to 60% recommended
Storage range: 10% to 90% non-condensing
Altitude
Note: For operations above 2.4 km (8,000 ft), decrease the operating temperature rating
by 1.8°C for each 1,000 m (1°F for each 1,000 ft).
Operating 2.4 km (8,000 ft)
Storage 9.1 km (30,000 ft)