Lantronix Hub Switch User Manual


 
MSS User Guide 2: Installation
2-14
Once the unit is running normally, the Power LED should be solidly lit to indicate the
unit is ON, the Link LED should be solidly lit to indicate a functioning Ethernet
connection, and the OK LED should blink green once every two seconds.
5. Supply power to the serial device.
6. Verify that the MSS is working. There are a few ways to check:
a) Wait for approximately 30 seconds after powering the unit up. If the Power and
Link LEDs are solidly lit and the OK LED blinks green once every two seconds,
the MSS is operating normally.
b) If you have connected a serial terminal to the MSS DB25 port, press the Return
key. You should see several lines of start-up messages followed by a Local>
prompt.
c) If an IP address is configured for the MSS, ping the MSS from a TCP/IP host. For
more instructions, see the IP Address Configuration section in Getting Started.
Figure 2-14: Pinging the MSS
% ping XXX.XXX.XXX.XXX
MSS100 Specifications
Power (power cube adaptor)
Adapter:
Input: 110 VAC US; 100-240 VAC International
Output: 5 VDC
Current: .74 amps
MSS100 power input requirement: 5 VDC regulated
Temperature
Note: Rapid temperature changes may affect operation. Do not operate near heating or
cooling devices or areas that open to the outdoors.
Operating range: 5° to 50° C (41° to 122° F)
Storage range: 40° to 66° C (-40° to 151° F)
Max. temp change: 20° C (36° F) per hour
Humidity
Operating range: 10% to 90% non-condensing
40% to 60% recommended
Storage range: 10% to 90% non-condensing
Altitude
Note: For operations above 2.4 km (8,000 ft), decrease the operating temperature rating
by 1.8°C for each 1,000 m (1°F for each 1,000 ft).
Operating 2.4 km (8,000 ft)
Storage 9.1 km (30,000 ft)