Command Reference Change Autobaud
2-11
PortList
Specify a particular port or group of ports. Port numbers are specified with
integers between 1 and 4, and should be separated with commas (for lists) or
dashes (for ranges).
Local
Permits only logins from the attached serial device.
Dynamic
Allows the port to initiate and receive connections.
Remote
Allows the port to accept network connection requests, but does not permit
local logins.
None
MSS4 only. Disables both outgoing and incoming connections for the
specified port(s).
Defaults Dynamic
See Also Change Autobaud, page 2-11.
2.4 Change Autobaud
Detects the baud rate used for an incoming connection to the specified port and then changes its own baud
rate at login time to match that of the remote device.
When Autobaud is enabled, you may have to press Return several times to help the MSS determine the
proper speed.
Restrictions Requires privileged user status.
Does not apply to the MSS485.
Errors Autobaud must be disabled for Dynamic and Remote port access.
Autobaud only works when a port is set for 8 bits with No parity or for 7 bits
with Even parity.
Autobaud and Autostart are incompatible. If the port is set for Autostart,
enabling Autobaud will disable Autostart, clear the Autostart character, and
produce an error message.
Parameters
Port
MSS4 only. Specifies a particular port or group of ports.
CHANGE
PORT PortList
AUTOBAUD
DISABLED
ENABLED


