Lantronix MSS Network Card User Manual


 
Command Reference LAT
2-60
Parameters
Delay
Schedules a reboot after a specified number of minutes.
num
Enter the number of minutes, from 0 (immediate) to 120.
Factory
Reboots the MSS with its factory-configured settings.
Noboot
Cycles power on the MSS, but without booting. The MSS will remain in the
Boot Configuration Program (BCP). See your installation guide for more
details on BCP.
Reload
Downloads operational software upon reboot.
See Also Appendix C, Updating Software.
2.78 LAT
Establishes a connection with a LAT service. If you do not specify a service or hostname, the MSS will
attempt a connection to the preferred host or service.
Errors Does not apply to MSSLite, MSS-VIA, or the MSS4.
Parameters
serviceName
Enter the name of the desired LAT service, for example, “modem”.
envString
Add the desired environment key(s). See Appendix B for a complete list of
strings. Options must be separated by colons.
Examples
Local> LAT modem:LD=port5
2.79 Logout Port
Logs out the serial port, disconnecting any existing sessions. For the MSS4, you can log out multiple serial
ports at once. Can also be used to log out modem card ports (Port 3 on the Via, Ports 5 and 6 for the MSS4).
Parameters
Port
Logs out the current port if entered by itself or, if used with the PortList
parameter, logs out the specified port.
LAT serviceName
:envString
LOGOUT
PORT PortList