Lantronix MSS Network Card User Manual


 
Command Reference Change Loginpass
2-31
2.31 Change Loginpass
Specifies the password used to log into the MSS. The password should consist of no more than 6 alphabetic
letters. Users are only required to provide this password if the port has Password Protect enabled.
If you do not enter the password at the command line, you will immediately be prompted to enter the new
password. This password is not displayed when typed.
Restrictions Requires privileged user status.
Parameters
Server
MSS4 only.
passwd
Enter a password of up to 6 alphabetic characters. When entered as part of the
command, the password should be enclosed by quotation marks to preserve
case.
Defaults access
Examples
CHANGE LOGINPASS “badger”
See Also Change Password Protect, page 2-38; Change Incoming, page 2-26.
2.32 Change Modem Control
Causes the MSS to treat any attached serial device as a modem. When enabled, a DSR drop will log out the
enabled port and the MSS will drop DTR for three seconds and then raise it when the port logs out. If
Autostart is also enabled, the port will not start until DSR is raised. The MSS supports partial modem control
(DSR/DTR).
Restrictions Requires privileged user status.
Does not apply to the MSS485.
Errors Modem Control must be disabled to use DSRLogout.
Parameters
Port
MSS4 only. Specifies a particular port or group of ports.
Note: In the absence of the PortList parameter, the configuration will affect the MSS4’s
current port only.
CHANGE
SERVER
LOGINPASS
passwd
CHANGE
PORT PortList
MODEM CONTROL
DISABLED
ENABLED


