Lantronix MSS Network Card User Manual


 
Command Reference Change Buffering
2-16
Remote
The MSS ignores the Break key and passes it to the remote host. Only
applicable if the session protocol supports Break events. Telnet supports Break
events, but Rlogin, raw TCP, and UDP do not.
None
Disables the Break key.
Defaults None
See Also Change Local Switch, page 2-30.
2.10 Change Buffering
Specifies the size of the buffer (in bytes) to use for network connections. The default size should be
sufficient in most cases.
Restrictions Requires privileged user status.
Parameters
Server
MSS4 only.
buffersize
Specify a size from 128 to 4096 (bytes).
Defaults 4096 bytes
2.11 Change Charsize
Sets the number of data bits per character for the specified serial port.
Restrictions Requires privileged user status.
Errors Autobaud will only work when a port is set for 8 data bits with No parity or for
7 data bits with Even parity.
The MSS100 can only use charsize 8 when parity is set to None. The MSS4
and MSS-VIA can have any parity with charsize 8.
Parameters
Port
MSS4 only. Specifies a particular port or group of ports.
Note: In the absence of the Portlist parameter, the configuration will affect the MSS4’s
current port only.
CHANGE
SERVER
BUFFERING buffersize
CHANGE
PORT PortList
CHARSIZE
7
8


