Lightwave Communications 3200 Server User Manual


 
10
5.0 Connecting Equipment to the ConsoleServer 3200
When connecting devices to the ConsoleServer 3200, be sure to use Lightwave
Communications cables and adapters to ensure the proper transmission of data signals.
If a device has an RJ45 serial port, use the manufacturer's cable included with the
equipment to convert the RJ45 serial connector to a DB9 or DB25 connector, and then
use a Lightwave Communications adapter to convert back to RJ45 to attach to the
device port. Directly connecting the RJ45 port on the ConsoleServer 3200 to the RJ45
port on a third-party device will not allow for the proper transmission of data signals.
ConsoleServer 3200 serial port default settings
Port Type Baud Rate Data Bits Parity Stop Bits Port Configuration
Terminal 38400 8 None 1 DCE
Device 9600 8 None 1 DCE
See Appendix A for further details on connectors and pinouts.
5.1 Terminal Card
Terminal Card typical adapters and port configuration:
System Type Adapter Part Number Port Configuration
Wyse 50 / 60 200.0066 DCE
DEC VT330, PC (25pin) 200.0067 DCE
PC (9pin) 200.0070 DCE
Materials:
ConsoleServer 3200 terminal port
terminal or computer with RS-232 serial port
RJ45-terminated Cat 5 cable (standard LAN cable)
Lightwave adapter for terminal serial port
1. Attach the Lightwave adapter to the terminal or computer serial port.
2. Connect the Cat 5 cable to the adapter. Connect the other end to the
ConsoleServer 3200 terminal port.
3. Turn on the terminal or start the computer’s communication program. Make sure
that the communication parameters of the terminal or computer match those of
the terminal port.