Lightwave Communications 3200 Server User Manual


 
73
Appendix C – System Specifications
C.1 Physical
Width: 17.25 inches (43.82 cm)
Depth: 14.75 inches (37.47 cm)
Height: 5.25 inches (13.34 cm)
Rack size: 3u high, mounts in EIA-standard 19-inch rack
Weight fully loaded: 20 lbs. (9.08 kg)
C.2 Environmental
Operating temperature range: 32°F (0°C) to 125°F (52°C)
Operating humidity range: 30% to 90% RH, non-condensing
Storage temperature range: -4°F (-20°C) to 158°F (70°C)
Storage humidity range: 10% to 90% RH, non-condensing
Heat generated in normal operation: 170.6 BTU/hr
C.3 Electrical
Both the AC and DC power versions of the ConsoleServer feature redundant power
supplies.
C.3.1 AC Power
Universal input voltage, auto-switched AC power supplies, switch fused
Input voltage: 115/230 VAC
AC frequency: 50/60 Hz
Maximum power consumption: 65 W
Typical power consumption: 50 W
C.3.2 DC Power
48 volt only, externally fused
Input voltage: -48 VDC
Maximum power consumption: 65 W
Typical power consumption: 50 W