Lucent Technologies MN102H75K Laptop User Manual


 
IR Remote Signal Receiver
IR Remote Signal Receiver Control Registers
MN102H75K/F75K/85K/F85K LSI User Manual Panasonic Semiconductor Development Company
225
Panasonic
RMIS: Remote Signal Interrupt Status Register x’007EA0’
RMIR indicates the detection and operation status of remote signal inter-
rupts. It is a 16-bit access register.
BCRSTE: 8-bit data reception binary counter reset enable
0: Disable
1: Enable
BCEDGS: 8-bit data reception binary counter reset edge select
0: Reset at 1st edge
1: Reset at 2nd edge
FMTMON: Format monitor
0: HEAMA format
1: 5-/6-bit format
DOMESD: Interrupt request on HEAMA leader detection
0: No request
1: Request
M56BITD: Interrupt request on 5-/6-bit leader detection
0: No request
1: Request
TRAILRD: Interrupt request on trailer detection
0: No request
1: Request
DAT8D: Interrupt request on 8-bit reception detection
0: No request
1: Request
EDGED: Interrupt request on RMIN pin edge detection
0: No request
1: Request
Bit:76543210
BC
RSTE
BC
EDGS
FMT
MON
DOMES
D
M56BIT
D
TRAILR
D
DAT8
D
EDGE
D
Reset:00000000
R/W: R/W R/W R R/W R/W R/W R/W R/W