Lucent Technologies P333T Switch User Manual


 
Cajun P333T User’s Guide 13
Chapter 4
Installation and Setup
The Cajun P333T is ready to work after you carry out the installation instructions
given below. All the Cajun P333T ports provide complete connectivity and no
configuration is required to make the system work.
Installing Stacking Sub-modules
Caution:
The stacking sub-modules contain components sensitive to electrostatic
discharge. Do not touch the circuit board unless instructed to do so.
Installing the Stacking Sub-module in the Cajun P330
1 Remove the blanking plate from the back of the Cajun P330 switch.
2 Insert the stacking sub-module gently into the slot, ensuring that the metal
base plate is aligned with the guide rails.
The metal plate of the X330STK (and
not
the PCB) fits onto the guide rails.
3 Press the sub-module in firmly until it is completely inserted into the
Cajun P330.
4 Gently tighten the two screws on the side panel of the stacking sub-module by
turning the screws.
Note:
The Cajun P330 switch must not be operated with the back-slot open; the
stacking sub-module should be covered with the supplied blanking plate if necessary.
Positioning
Cajun P333T can be mounted alone or in a stack in a standard 19-inch equipment
rack in a wiring closet or equipment room. Up to 10 units can be stacked in this
way. When deciding where to position the unit, ensure that:
It is accessible and cables can be connected easily and according to the
configuration rule.
Cabling is away from sources of electrical noise such as radio transmitters,
broadcast amplifiers, power lines and fluorescent lighting fixtures.
Water or moisture cannot enter the case of the unit.
Air-flow around the unit and through the vents in the back and sides of the
case is not restricted.
Note:
Use Octaplane cables to interconnect with other switches.