Lucent Technologies P333T Switch User Manual


 
62 Cajun P333T User’s Guide
Environmental
Safety
AC
UL for US approved according to UL195O Std.
C-UL(UL for Canada) approved according to C22.2 No.950 Std.
CE for Europe approved according to EN 60950 Std.
Laser components are Laser Class I approved:
EN-60825/IEC-825 for Europe
FDA CFR 1040 for USA
Safety
DC
Restricted Area Access: This device should only be installed in a restricted
access area.
Installation Codes: This device must be installed in accordance with the US
National Electrical Code, Articles 110-26 and 110-27, and the Canadian
Electrical Code, Section 12.
Overcurrent Protection: A readily accessible Listed branch-circuit overcurrent
protective device with a 15A rating must be incorporated in the building
wiring.
EMC Emissions
Emissions
Approved according to:
US -FCC Part 15 sub part J, class A
Europe - EN55022 class A
Immunity
Approved according to:
EN 50082-1
Interfaces
24 x 10/100BASE-T RJ45 port connectors.
RS-232 for terminal setup via RJ45 connector on front panel.
Operating Temp. -5 – 50
0
C (23-122
0
F)
Rel. Humidity 5% to 95% non-condensing